The probe-holder fitting of this series is useful to install temperature probes in pocket. The fitting has an O-Ring seal for the thread and a dowel screw to lock the the probe in the pocket.
Working temperature range: 0 (no frost)110 °C
Max working pressure: 16 bar
Probe diameter: 6 mm
Probe holder lenght: 50 mm
Probe holder lenght totally immersed in fluid: 33 mm
Suitable fluids: water for thermal systems, glycol solutions (max 50%), domestic water
Threaded connections: ISO 228-1
CODICE_ARTICOLO | size | NPS | NPC |
---|---|---|---|
x | - | - | - |
P28015000I4 | G 1/2 M | 10 | 50 |